Low dose microcomputed tomography (μCT) is a recently matured technique that enables the study of longitudinal bone healing and the testing of experimental treatments for bone repair. This imaging technique has been used for studying craniofacial repair in mice but not in an orthopedic context. This is mainly due to the size of the defects (approximately 1.0 mm) in long bone, which heal rapidly and may thus negatively impact the assessment of the effectiveness of experimental treatments. We developed a longitudinal low dose μCT scan analysis method combined with a new image segmentation and extraction software using Hounsfield unit (HU) scores to quantitatively monitor bone healing in small femoral cortical defects in live mice. We were able to reproducibly quantify bone healing longitudinally over time with three observers. We used high speed intramedullary reaming to prolong healing in order to circumvent the rapid healing typical of small defects. Bone healing prolongation combined with μCT imaging to study small bone defects in live mice thus shows potential as a promising tool for future preclinical research on bone healing.
1. Introduction
Bone healing is a constantly growing field of research with important clinical implications. Precise and effective monitoring of bone healing is thus essential. Histological preparations are traditionally used to assess tissue composition and bone repair processes. However, they are limited to two-dimensional analyses of three-dimensional (3D) structures and semiquantitative scoring systems. Biomechanical testing is also a reliable quantitative method for assessing bone repair but is limited to endpoint analyses, as are histological preparations [1]. Because of high inter- and intrasubject variability, such studies involving several time points require large numbers of animals, which increases the cost of labor-intensive experiments [2].
The use of µCT in experimental medicine has increased exponentially over the past few years because this imaging technique provides reliable and highly reproducible results [3]. µCT imaging enables both noninvasive, tissue-preserving imaging and quantitative 3D morphometry of bone structures, notably of woven bone [4, 5], and has thus rapidly evolved to become the gold standard for microarchitecture analyses [6, 7]. Longitudinal low dose µCT analyses have been used to study treatments for enhancing the healing of calvarial defects in murine models [8–11] and to quantify tumor-induced osteolysis [12]. However, µCT data collection often requires ex vivo specimens, meaning that the animals have to be sacrificed [6]. While a few investigators have reported using low dose µCT to study bone architecture in vivo [13–15], none has used longitudinal µCT scans to evaluate the healing of drill hole cortical defects in mice, mainly because spontaneous healing occurs quickly, making it difficult to assess the effect of treatments on bone healing [16]. To slow down spontaneous bone healing, Gao et al. irradiated the limbs of mice to reduce the contribution of endogenous cells to bone healing [17], while effective irradiation impairs nonstem cell therapies, such as growth factors that stimulate the recruitment and differentiation of the endogenous progenitors required for bone repair.
In the present study, we used low dose µCT imaging to perform longitudinal quantitative analyses of bone healing of femoral cortical defects in mice. To assess bone healing, we performed longitudinal µCT scans of live animals using a dedicated small-animal low dose µCT scanner and analyzed the images using custom semiautomated segmentation and coregistration software. Despite creating noncritical size femoral defects, our results enabled us to show that intramedullary reaming is effective in slowing down spontaneous bone healing and significantly increasing the time required for the defect to heal. In summary, the combination of low dose µCT scan imaging of live animals and bone reaming appears to be a valuable tool for evaluating the kinetics of long bone healing following treatments with drugs, biomaterials, and/or cells in mice.
2. Materials and Methods2.1. Animals
Skeletally mature 12- to 16-week-old male CD1 (Charles River, Saint-Constant, QC, Canada) mice were used. This study was carried out in strict accordance with the recommendations in the Guide for the Care and Use of Laboratory Animals of the National Institutes of Health. The protocol was approved by the Committee on the Ethics of Animal Experiments of the University of Sherbrooke (Permit Number 141-11B). Prior to surgery, the mice received a narcotic (Buprenorphine; 0.05–0.1 mg/kg) to control pain as well as a preventive dose of antibiotic (penicillin G; 60,000 U).
2.2. Surgical Procedure for Creating Femoral Cortical Defects and Reaming the Medullar Cavity
A diaphyseal cortical defect of the anterodistal femur was created using a modified drill hole technique [18, 19] with or without intramedullary reaming as shown in Figure 1. Briefly, the mice were anesthetized (isoflurane), their limbs were shaved, and the skin was disinfected using a 0.5% chlorhexidine solution (Dexidin 0.5; Atlas Laboratory, Montreal, QC, Canada). A skin incision was made to expose the medial quadriceps and knee. A medial parapatellar approach was then made to the knee and was extended proximally through the quadriceps to expose the distal femur by lateral patellar eversion. A 3/64′′ drill bit (Model 865; Dremel, Mount Prospect, IL, USA) was used to create a 1.1 mm-diameter circular defect in the anterior cortex of both femurs 4 mm above the femoral condyles. The defects were irrigated with normal saline to remove bone residues. Intramedullary reaming was performed on one femur by drilling a 1/32′′-hole through the intercondylar notch and then reaming the full length of the medullar cavity. The reamer was kept in the medullar cavity at high speed for 10 s.
Surgical procedure for creating diaphyseal femoral cortical defects and intramedullary reaming. The femur was exposed (a) and the quadriceps was reclined by everting the patella (b). A cortical defect was created in the distal midshaft portion of the femur using a drill bit (c). Reaming was performed by drilling through the intercondylar notch of the femur (d).
The defects were then covered by reclining the quadriceps back to its original position and repositioning the patella. The incision was closed using nonabsorbable sutures. The surgery was performed by an orthopedic surgeon using sterile materials in aseptic conditions. The mice were used for live µCT imaging and/or were euthanized for histological examinations.
Low dose µCT scan imaging was performed using a Gamma Medica Triumph X-O small-animal CT scanner composed of a 40 W X-ray tube with a 75 µm focal spot diameter and a 2240 × 2368 CsI flat panel X-ray detector. The detector pixel size was 50 µm, and a 2 × 2 pixel binning scheme was used. Scans were performed at 60 kVp and 230 µA using 512 projections in fly mode to reduce exposure with a 59.20 mm FOV. Images were reconstructed using the general purpose reconstruction FBP kernel from the Gamma Medica software over an isotropic 116 µm voxel spacing grid providing a voxel volume of 1.56 × 10−3 mm3. Air and water phantoms (15 mL Falcon tubes) were scanned for each imaging session to allow normalization in HU. The live mice were scanned once prior to surgery as a control and then at days 0 (immediately after surgery), 7, 14, 21, 30, 35, 44, 57, and 78 after surgery. To minimize movement, the mice were isoflurane-sedated during the µCT imaging. The dose of radiation administered was 11.7 cGy per scan, as measured by dosimeter.
2.4. Software to Quantify Bone Healing
Custom software was written to automatically calculate the size of the cortical defects. The µCT scans consisted of 512 individual image slices stacked in a RAW file and converted to the NIFTI format using Fiji freeware (ImageJ, Version 1.42q; National Institutes of Health, USA) [20]. ITK-SNAP freeware (http://www.itksnap.org) was used to segment structures [21] and manually delineate 3D ROI on the cortical defects in the postsurgery (day 0) scans. Tracing an irregular anatomic contour adjacent to the cortical surface was deemed the best approach to create the 3D ROI. We used software provided by the Image Analysis and Visualization Platform (PAVI, Sherbrooke, QC) to virtually extract, align, and save images of each mouse femur to smaller volumes. The virtually extracted femurs were then registered to the day 0 postsurgery reference femur using FSL Flirt [22, 23]. Since we did not want the spatial information of the bones to be lost, we parameterized Flirt to use a rigid body transformation with 6 degrees of freedom. After registration, a linear transformation was applied to the voxel signal intensities to convert them to the HU [24] scale using water for calibration. This allowed the signals from different scans made at different time points to be calibrated. The HU scale makes it possible to conduct analyses of absolute voxel signal intensities in order to determine the material density in each voxel (bone, muscle, water, etc.). We then calculated the kinetics of cortical defect healing using the previously determined 3D ROI, which became relevant for each time point after registration. The volumes and sizes of the cortical defects in treated and control femurs for each mouse were then quantified over time as were their densities based on the HU scale. The HU ranges for empty or soft tissue reaction (e.g., hematoma) (−1000 to +800 HU), woven bone (+1200 to +1900 HU), and compact bone (>2700 HU; comparable to intact bone) were based on published results from other groups [25–27] as well as on results from specific anatomical sites with known tissue compositions.
2.5. Statistics
To calculate the sample size required, we used the following repeated sample size estimation formula, (n=2+C(s/d)^2), where s is the standard deviation and d is the difference measured, with a C of 7.85, a power of 80%, and an alpha of 0.05. The difference d was measured between the volumes of the cortical deficits in the left and right femurs on postoperative day 29 when the dissimilarity between the two femurs was the most marked. The standard deviation was also calculated using the results on postoperative day 29. The standard deviation was 0.255, and the measured difference was 0.36. The sample size required for a significant result was thus at least 6 mice.
One outcome of the study was the assessment of the agreement among three observers with respect to their 3D ROI determinations for the same µCT scan. This was represented by a Bland-Altman plot [28]. Graphically, the mean differences and the 95% confidence intervals (CI) were represented. An intraclass coefficient (ICC) was also used to assess their reliability and validity. The ICC for the interobserver agreement was obtained by comparing blind measurements of the three observers. For clinical studies, a Cronbach alpha value over 0.85 is considered very good, while a value over 0.9 is considered “ideal” [29].
The main outcome of the present study was to assess the differences in 3D ROI voxel HU cortical defect volumes between the reamed and unreamed femurs relative to the respective postoperative day 0 volumes. The comparison of means between reamed and unreamed samples at the same time point was analyzed using two-way ANOVA and Sidak’s multiple comparisons test. P values less than 0.05 were considered significant.
Statistical analyses were performed using SPSS v20.0.0, and the results were graphed using Prism v5.0.
3. Results3.1. 3D ROI: Analysis of Interobserver Agreement
Since initial 3D ROI segmentation may be subjective and thus overestimate or underestimate healing, we verified the interobserver agreement, which was represented using Bland-Altman plots (Figure 2). We used three observers (A-B-C) to blindly determine the 3D ROI of the defects. The results are presented as the difference in the absolute number of voxels per 3D ROI as a function of the average size of the defect. Of the 36 scans, 18 were of femurs with a defect but no reaming (Figure 2(a)) and 18 were of femurs with a defect and reaming (Figure 2(b)). The two-by-two comparison of the three observers (A-B, B-C, and C-A) showed that the 95% confidence interval of the evaluations of the observers ranged from −226.5 to +226.4 (21.9% ± 5.0) and from −245.9 to +247.1 (20.1% ± 3.2) for defects without reaming and defects with reaming, respectively.
Interobserver agreement in the determination of 3D ROI. A Bland-Altman plot was used to graph differences in the absolute number of voxels per 3D ROI as a function of the average size of the defect. This made it possible to assess the agreement between three observers in the determination of the 3D ROI. Eighteen µCT images from (a) unreamed femurs with a defect and (b) reamed femurs with a defect were blindly analyzed. The two-by-two comparison of the three observers (A-B, B-C, and C-A) showed a 95% confidence interval from −226.5 to +226.4 and from −245.9 to +247.1 for unreamed femurs with a defect and reamed femurs with a defect, respectively. An interclass correlation (ICC) was used to compare interobserver variability. The ICC scores were 0.864 (very good, P<0.0001) and 0.905 (ideal, P<0.0001) for the unreamed femurs with a defect and the reamed femurs with a defect, respectively.
To determine whether the interobserver agreement was significant, we calculated an interclass correlation (ICC), which allowed us to compare interobserver variability for a given sample. The ICC was 0.864 (very good, P<0.0001) for the defect without reaming and 0.905 (ideal, P<0.0001) for the defect with reaming, indicating very good interobserver agreement. In addition, there was no significant difference between the 3D ROI of the defect without reaming and the defect with reaming.
3.2. Longitudinal Low Dose µCT Analysis of Bone Healing
We determined the difference in the kinetics of bone healing between reamed and unreamed femurs by calculating the number of voxels in nonorganized substrate, woven bone, and compact bone. Figure 3(a) shows reconstructed images of anteroposterior views of the femurs with their defects on days 0 and 21 as well as on day 57 after surgery, when the most significant variations in tissue composition of the reamed and unreamed femurs were observed. In addition to visualizing the registration of the femurs at different times, it is possible to identify the position of the 3D ROIs overlaid on the defects along different views (Figure 3(b)). Cross-sectional views of the femurs can also be seen in which the 3D ROI is apparent (Figure 3(c)). In both representations, the voxels of the 3D ROI are color-coded to differentiate between the various components in the defect, that is, empty/soft tissue reaction (red), woven bone (blue), and compact bone comparable to intact bone (green). Figures 3(b) and 3(c) show that woven bone and compact bone formation is delayed in the reamed preparation compared to the unreamed preparation.
Bone healing monitoring as a function of time using low dose µCT scans of live mice. (a) Representative views of 3D µCT reconstructed images of femurs on days 0, 21, and 57 after surgery. Variations in the density of the 3D ROI (determined at day 0 after surgery) make it possible to estimate the tissue composition. (b) 3D ROI can also be observed in axial, coronal, and sagittal views. (c) Representative cross-sectional views of the femur in which the 3D ROI is apparent in one image (slice). The colored voxels make it possible to see changes in defect composition as a function of time where most of the voxels were red on day 0 and blue on day 28, with an increasing proportion of green on day 57. Nonorganized substrate (red: −1000 to +800 HU), woven bone (blue: +1200 to +1900 HU), and compact bone (green; >2700 HU).
We used our custom software to verify the filling kinetics of the defects (Figure 4(a)). Graphing the percentage of voxels in the −1000 to +800 HU range within the 3D ROI over time revealed that reaming caused a significant delay in healing. It took 11 and 16 days after surgery for 50% healing to occur in the unreamed and reamed femurs, respectively, while 75% healing took approximately 16 and 36 days, respectively. By day 57, there was no significant difference in healing between the two surgical procedures.
Bone healing as a function of time for a defect without reaming and a defect with reaming. (a) The results were quantified and plotted as a percentage of voxels representing nonorganized material as a function of time for unreamed femurs with a defect and reamed femurs with a defect. The percentages of (b) woven and (c) dense bone formation as a function of time were also graphed. The results were obtained from nine mice (n=9; P*<0.05, P***<0.0001).
We also assessed the formation of woven bone by graphing the percentage of voxels in the +1200 to +1900 HU range within the 3D ROI as a function of time (Figure 4(b)). The percentage of voxels related to woven bone was significantly higher in the unreamed preparations, with the percentage reaching a plateau around day 29 of 40% and 29% for the unreamed and reamed preparations, respectively. Interestingly, the percentages decreased to 20% by day 57, when no significant difference between the preparations was observed.
We investigated the formation of compact bone by graphing the percentage of voxels in the 3D ROI with >2700 HU as a function of time (Figure 4(c)). The percentage of voxels related to dense bone increased significantly faster in the unreamed femurs than in the reamed femurs. This difference was observed by day 35, when the percentage reached 30% for the unreamed femurs but only 8% for the reamed femurs. The percentage increased until day 57, reaching nearly 40% for the unreamed femurs and nearly 22% for the reamed femurs.
4. Discussion
µCT is a precise tool for bone imaging, and in recent decades it has been shown to be the gold standard for studying bone structure [30]. It has been shown to be a relevant tool for craniofacial studies in small rodents, in which it is possible to create critical size bone or nonhealing defects [8–11]. Unfortunately, such critical size defects cannot be created in the long bones of mice without using nails or other materials that can impair µCT imaging [31, 32]. On the other hand, small noncritical size bone defects heal spontaneously and rapidly, which may hinder the effectiveness of experimental treatments [16]. To widen this “therapeutical” window, we reamed the endosteum of the medullar region of the bone. The aim of our study was to evaluate the utility of using longitudinal low dose µCT scans to assess the healing of noncritical size defects (1 mm) in long bones in mice and to investigate the effect of intramedullary reaming on healing times.
Longitudinal studies of small cortical defects using low dose µCT scan are challenging for many reasons. First, bone defects created using small drill bits are subject to operator bias due to differences in the angle at which the drill bit enters the femur and due to micromovements once the bit is fully introduced. This bias must be taken into account given the size of the defects (1 mm), which are much smaller than calvarial defects, which can be up to 5 mm in diameter in mice [8]. Second, small defects are assessed using multiple scans of the animals, which, while immobilized, are not in exactly the same position, which in turn increases the risk of miscalculations. To circumvent these experimental biases, the corresponding femur of each animal was first rigorously aligned in space, making it possible to exactly superpose the 3D ROI. The 3D ROIs at day 0 (after operation) were then set and their coordinates were applied to all time points. The results of each time point were relativized to the initial 3D ROI at day 0 (before and after operation). By applying this procedure, we were able to assess callus formation and mineralization over time by using calibrated voxels expressed in HU that were applied to different tissue composition categories, that is, empty or soft tissue reaction (e.g., hematoma), woven bone, and mineralized compact bone. More importantly, the bone healing process over time described in the present study matched that of previous µCT and histological studies [33–35].
In addition, our results showed that the healing of cortical defects is significantly affected by the endosteal reaming procedure. This was shown by the significant delay in defect filling and the formation of woven and compact bone over time. In terms of compositional analyses, Hayward et al. suggested that the use of contrast-enhanced µCT scans may improve the evaluation of nonmineralized (e.g., cartilage) and mineralized tissues in fracture calluses [36]. From our experience, we had no difficulty in distinguishing between these tissues. This may be due to the ranges of HU that we used to categorize the tissues and the use of the 3D ROI at day 0 (prior to surgery) as a reference. Our software made it possible to follow changes in the tissue density of a healing region as small as 1 mm3. Low dose µCT analyses may thus provide a reasonable estimate of the tissue mineralization of healing bone based on HU.
Our study also showed that appropriate analysis software and suitable image resolution limit observer variability. Since our software relies on manual tracings of an initial volume of interest (3D ROI) on native µCT scans, interobserver differences may occur given that the exact delineation of cortical defects depends partly on the judgment of the observers. We hypothesized that the greatest interobserver variability is caused by the semisubjective delineation of the initial cortical defect, which is a bias that may be compounded. However, our ICC interobserver analysis showed that this bias is small for experienced observers and does not affect the results. Alternatives include global and local threshold segmentation, but since our 3D ROI was relatively small and well delineated, we judged that manual tracing segmentation would be the most convenient. This finding also implied that, depending on the type of experiment, investigators should choose the appropriate µCT resolution to maintain an acceptable level of precision.
While low dose µCT scans have limited resolution compared to high dose scans, our study showed that the resolution is sufficient and, importantly, low dose scans avoid the biological risk associated with repeated radiation exposure [37–40]. Laperre et al. reported that they observed no hematological toxicity or radiotoxic effect on bone microarchitecture with triple radiation doses of 43.4 cGy per scan [39], which correspond to a cumulative dose of 130 cGy. In our study, the cumulative dose was under 120 cGy, which is far less than 200 cGy, the dose at which the tumor risk increases in mice, thus making any radiation-induced effect on bone healing unlikely [41].
The creation of defects by drilling a hole in the bone cortex is a widely used and effective model for studying bone healing [16, 35], and it is well known that it leads to spontaneous healing [16, 42]. Many reasons could explain the healing delay observed in the reamed preparations. Previous studies have shown that vascular compromise can induce a significant healing delay or even nonunion in rodent fracture models [43, 44]. Since medullar vascularization accounts for about two-thirds of total bone vascularization [45], it is reasonable to think that its disruption could increase healing time. In addition, a loss of medullar substance and endosteum may also contribute to the delay in healing since they contain progenitor cells that contribute to bone healing [35, 46]. Other groups have used different approaches to slow down spontaneous bone healing. To assess how transplanted MSC contribute to healing cortical bone defects, Gao et al. sublethally irradiated the hindlimbs of mice in order to prevent endogenous MSC from participating in the cortical healing process [17]. Prolonging bone healing by medullar reaming may be a useful and simple procedure for limiting spontaneous healing and widening the window for studying the effect of compounds and exogenous stem cells.
5. Conclusion
We showed that low dose µCT scans can be used to quantify and characterize bone healing in live mice. Using 3D ROI coordinates determined immediately following surgery, it was possible to evaluate variations in tissue density within the 3D ROI and show that reaming delays the healing of cortical defects in mice. The proposed experimental approach reduces the number of animals needed, provides quantitative longitudinal results, and is reproducible between different observers. Bone healing prolongation combined with µCT imaging to study small bone defects in live mice thus shows potential as a promising tool for future preclinical research on bone healing.
Conflict of Interests
The authors declare that there is no conflict of interests regarding the publication of this paper.
Acknowledgments
The authors are grateful to Dr. David Alcoloumbre, Dr. Otman Sarrhini, and Geneviève Drouin for their assistance and Drs. Maxime Descoteaux, Matthieu Dumont, and Félix C. Morency from PAVI. Lu-Zhao Di is the recipient of a scholarship from the Canadian Institutes of Health Research (CIHR). Élisabeth Leblanc is the recipient of scholarships from the Fondation pour la Recherche et l’Enseignement en Orthopédie de Sherbrooke (FREOS) and CIHR. Guillaume Grenier holds a New Investigator Award from the Fonds de Recherche du Québec-Santé (FRQS). This work was supported by grants from CIHR, the National Science and Engineering Research Council of Canada (NSERC), the Canada Foundation for Innovation (CFI), and the Réseau de Thérapie Cellulaire du FRQS (ThéCell). The Centre d’imagerie moléculaire de Sherbrooke is part of the FRQS-funded CRCHUS.
ParfittA. M.DreznerM. K.GlorieuxF. H.KanisJ. A.MallucheH.MeunierP. J.OttS. M.ReckerR. R.Bone histomorphometry: standardization of nomenclature, symbols, and units. Report of the ASBMR Histomorphometry Nomenclature Committee1987265956102-s2.0-0023488581OetgenM. E.MerrellG. A.TroianoN. W.HorowitzM. C.KacenaM. A.Development of a femoral non-union model in the mouse200839101119112610.1016/j.injury.2008.04.0082-s2.0-50249099181GriffithJ. F.GenantH. K.Bone mass and architecture determination: state of the art200822573776410.1016/j.beem.2008.07.0032-s2.0-56349125209FeldkampL. A.GoldsteinS. A.ParfittA. M.JesionG.KleerekoperM.The direct examination of three-dimensional bone architecture in vitro by computed tomography1989413112-s2.0-0024589979KinneyJ. H.LaneN. E.HauptD. L.In vivo, three-dimensional microscopy of trabecular bone19951022642702-s2.0-0028910321BouxseinM. L.BoydS. K.ChristiansenB. A.GuldbergR. E.JepsenK. J.MüllerR.Guidelines for assessment of bone microstructure in rodents using micro-computed tomography20102571468148610.1002/jbmr.1412-s2.0-77954756294JonesA. C.ArnsC. H.SheppardA. P.HutmacherD. W.MilthorpeB. K.KnackstedtM. A.Assessment of bone ingrowth into porous biomaterials using MICRO-CT20072815249125042-s2.0-3384766154110.1016/j.biomaterials.2007.01.046CowanC. M.ShiY.-Y.AalamiO. O.ChouY.-F.MariC.ThomasR.QuartoN.ContagC. H.WuB.LongakerM. T.Adipose-derived adult stromal cells heal critical-size mouse calvarial defects200422556056710.1038/nbt9582-s2.0-2342586660CowanC. M.AghalooT.ChouY.-F.WalderB.ZhangX.SooC.TingK.WuB.MicroCT evaluation of three-dimensional mineralization in response to BMP-2 doses in vitro and in critical sized rat calvarial defects200713350151210.1089/ten.2006.01412-s2.0-34147201090AghalooT.CowanC. M.ChouY.-F.Nell-1-induced bone regeneration in calvarial defects2006169390391510.2353/ajpath.2006.0512102-s2.0-33748807766ParkS.-Y.KimK.-H.KooK.-T.LeeK.-W.LeeY.-M.ChungC.-P.SeolY.-J.The evaluation of the correlation between histomorphometric analysis and micro-computed tomography analysis in AdBMP-2 induced bone regeneration in rat calvarial defects20114152182262-s2.0-8485976644710.5051/jpis.2011.41.5.218JohnsonL. C.JohnsonR. W.MunozS. A.MundyG. R.PetersonT. E.SterlingJ. A.Longitudinal live animal micro-CT allows for quantitative analysis of tumor-induced bone destruction201148114115110.1016/j.bone.2010.05.0332-s2.0-78650304408WaarsingJ. H.DayJ. S.WeinansH.An improved segmentation method for in vivo μCT imaging200419101640165010.1359/JBMR.0407052-s2.0-18044371462WaarsingJ. H.DayJ. S.van Der LindenJ. C.EderveenA. G.SpanjersC.de ClerckN.SasovA.VerhaarJ. A. N.WeinansH.Detecting and tracking local changes in the tibiae of individual rats: a novel method to analyse longitudinal in vivo micro-CT data200434116316910.1016/j.bone.2003.08.0122-s2.0-0942268148DavidV.LarocheN.BoudignonB.Noninvasive in vivo monitoring of bone architecture alterations in hindlimb-unloaded female rats using novel three-dimensional microcomputed tomography20031891622163110.1359/jbmr.2003.18.9.1622HendersonJ. E.GaoC.HarveyE. J.DuqueG.WatanabeK.Skeletal phenotyping in rodents: tissue isolation and manipulation2011London, UKSpringerGaoC.SeuntjensJ.KaufmanG. N.Mesenchymal stem cell transplantation to promote bone healing20123081183118910.1002/jor.220282-s2.0-84862753004HeY.-X.ZhangG.PanX.-H.Impaired bone healing pattern in mice with ovariectomy-induced osteoporosis: a drill-hole defect model20114861388140010.1016/j.bone.2011.03.7202-s2.0-79955923309NagashimaM.SakaiA.UchidaS.TanakaS.TanakaM.NakamuraT.Bisphosphonate (YM529) delays the repair of cortical bone defect after drill-hole injury by reducing terminal differentiation of osteoblasts in the mouse femur20053635025112-s2.0-1554438805410.1016/j.bone.2004.11.013AbramoffM. D.MagelhaesP. J.RamS. J.Image processing with imageJ20041173642YushkevichP. A.PivenJ.HazlettH. C.User-guided 3D active contour segmentation of anatomical structures: significantly improved efficiency and reliability20063131116112810.1016/j.neuroimage.2006.01.0152-s2.0-33744930583GreveD. N.FischlB.Accurate and robust brain image alignment using boundary-based registration2009481637210.1016/j.neuroimage.2009.06.0602-s2.0-67949092690JenkinsonM.BannisterP.BradyM.SmithS.Improved optimization for the robust and accurate linear registration and motion correction of brain images200217282584110.1016/S1053-8119(02)91132-82-s2.0-0036425968HounsfieldG. N.Computed medical imaging19802104465222810.1126/science.69979932-s2.0-0019198182KatsumataA.HirukawaA.OkumuraS.NaitohM.FujishitaM.ArijiE.LanglaisR. P.Effects of image artifacts on gray-value density in limited-volume cone-beam computerized tomography200710468298362-s2.0-3614893722410.1016/j.tripleo.2006.12.005MahP.ReevesT. E.McDavidW. D.Deriving Hounsfield units using grey levels in cone beam computed tomography201039632333510.1259/dmfr/196033042-s2.0-77956204072DonneysA.NelsonN. S.DeshpandeS. S.BoguslawskiM. J.Tchanque-FossuoC. N.FarbergA. S.BuchmanS. R.Quantifying mineralization using bone mineral density distribution in the mandible2012235150215062-s2.0-8486777310810.1097/SCS.0b013e3182519a76BlandJ. M.AltmanD. G.Applying the right statistics: analyses of measurement studies2003221859310.1002/uog.1222-s2.0-0038675123BlandJ. M.AltmanD. G.Cronbach's alpha19973147080, article 57210.1136/bmj.314.7080.5722-s2.0-8044252153TremoledaJ. L.KhalilM.GompelsL. L.Wylezinska-ArridgeM.VincentT.GsellW.Imaging technologies for preclinical models of bone and joint disorders2011111142-s2.0-8487591223110.1186/2191-219X-1-11De ManB.NuytsJ.DupontP.MarchalG.SuetensP.Metal streak artifacts in X-ray computed tomography: a simulation study199946346447210.1109/23.7756002-s2.0-0033321436CookS. D.PatronL. P.SalkeldS. L.SmithK. E.WhitingB.BarrackR. L.Correlation of computed tomography with histology in the assessment of periprosthetic defect healing2009467123213322010.1007/s11999-009-1087-02-s2.0-70449341687UusitaloH.RantakokkoJ.AhonenM.A metaphyseal defect model of the femur for studies of murine bone healing200128442342910.1016/S8756-3282(01)00406-92-s2.0-0035034774CampbellT. M.WongW. T.MackieE. J.Establishment of a model of cortical bone repair in mice2003731495510.1007/s00223-002-2120-42-s2.0-0042889307MonfouletL.RabierB.ChassandeO.FricainJ.-C.Drilled hole defects in mouse femur as models of intramembranous cortical and cancellous bone regeneration201086172812-s2.0-7364910779610.1007/s00223-009-9314-yHaywardL. N. M.De BakkerC. M. J.GerstenfeldL. C.GrinstaffM. W.MorganE. F.Assessment of contrast-enhanced computed tomography for imaging of cartilage during fracture healing201331456757310.1002/jor.222652-s2.0-84874667144YuL.LiuX.LengS.Radiation dose reduction in computed tomography: techniques and future perspective200916584Duran-StruuckR.DyskoR. C.Principles of bone marrow transplantation (BMT): providing optimal veterinary and husbandry care to irradiated mice in BMT studies200948111222-s2.0-61349149941LaperreK.DepypereM.van GastelN.Development of micro-CT protocols for in vivo follow-up of mouse bone architecture without major radiation side effects201149461362210.1016/j.bone.2011.06.0312-s2.0-80052295768KlinckR. J.CampbellG. M.BoydS. K.Radiation effects on bone architecture in mice and rats resulting from in vivo micro-computed tomography scanning200830788889510.1016/j.medengphy.2007.11.0042-s2.0-50249117635CrumpK. S.DuportP.JiangH.ShilnikovaN. S.KrewskiD.ZielinskiJ. M.A meta-analysis of evidence for hormesis in animal radiation carcinogenesis, including a discussion of potential pitfalls in statistical analyses to detect hormesis20121532102312-s2.0-8485944868710.1080/10937404.2012.659140BoschC.MelsenB.VargervikK.Importance of the critical-size bone defect in testing bone-regenerating materials19989431031610.1097/00001665-199807000-000042-s2.0-0031818419HietaniemiK.PeltonenJ.PaavolainenP.An experimental model for non-union in rats1995261068168610.1016/0020-1383(95)00135-22-s2.0-0029557995LuC.MiclauT.HuD.MarcucioR. S.Ischemia leads to delayed union during fracture healing: a mouse model200725151612-s2.0-3384607428510.1002/jor.20264RhinelanderF. W.EdwardsC. C.Thevascular response of bone to internal fixation1987Philadelphia, Pa, USALea & Febiger2529ColnotC.Skeletal cell fate decisions within periosteum and bone marrow during bone regeneration200924227428210.1359/jbmr.0810032-s2.0-58649117944