In water-cooled reactor, the dominant radioactive source term under normal operation is activated corrosion products (ACPs), which have an important impact on reactor inspection and maintenance. A three-node transport model of ACPs was introduced into the new version of ACPs source term code CATE in this paper, which makes CATE capable of theoretically simulating the variation and the distribution of ACPs in a water-cooled reactor and suitable for more operating conditions. For code testing, MIT PWR coolant chemistry loop was simulated, and the calculation results from CATE are close to the experimental results from MIT, which means CATE is available and credible on ACPs analysis of water-cooled reactor. Then ACPs in the blanket cooling loop of water-cooled fusion reactor ITER under construction were analyzed using CATE and the results showed that the major contributors are the short-life nuclides, especially Mn-56. At last a point kernel integration code ARShield was coupled with CATE, and the dose rate around ITER blanket cooling loop was calculated. Results showed that after shutting down the reactor only for 8 days, the dose rate decreased nearly one order of magnitude, which was caused by the rapid decay of the short-life ACPs.
In the cooling loop of water-cooled reactor, the oxidation and corrosion of the metal material by water are inevitable, and part of the corrosion products will be activated under neutron irradiation and become radioactive, which are called activated corrosion products (ACPs). Some ACPs continuously decay and emit harmful gamma-rays even after shutdown of the reactor for a long time. According to the surveillance data from French PWR plants, more than 90% of integrated dose under normal operation is due to ACPs [
Because of the importance of ACPs, the relevant research was started since 1960s in PWR plants, and many codes have been developed [
The basic theory and equations of the three-node transport model were described in the second section of this paper, and ACPs in MIT PWR coolant chemistry loop and ITER blanket cooling loop were calculated using the code CATE, respectively, in the third section and the fourth section. Then the dose rate around ITER blanket cooling loop caused by ACPs was calculated using the point kernel integration code ARShield in the fifth section. In the last section, a comprehensive comment was presented.
In the model, the cooling loop is divided into three nodes, which are the in-flux pipe, the coolant, and the out-flux pipe. The corrosion products transport between the nodes is by means of dissolution and deposition. Nickel ferrite is the main corrosion products in the cooling loop, and it shows an inverse solubility curve with temperature. As the coolant temperature changes around the cooling loop, the saturation status of the corrosion products in the coolant also changes. In the region of out-flux (e.g., the heat-exchanger), as the coolant temperature decreases, the soluble species become undersaturated, so that there is a driving force for the corrosion products on the pipe surface to dissolve into the coolant to restore a saturation concentration of corrosion products in the coolant. On the other hand, in the region of in-flux (e.g., the core in PWR or the blanket in fusion reactor), where the coolant temperature increases, the soluble species exist in a supersaturated state, so that there is a driving force for the soluble species to deposit on the pipe surface. Through this process, the corrosion products are transported from the out-flux pipe to the in-flux pipe.
In the region of in-flux, part of the corrosion products absorb neutrons and become ACPs. The ratio of ACPs to corrosion products on the pipe surface is larger than that in the coolant, so there is a net flow of ACPs from the pipe surface to the coolant by isotope exchange. In the region of out-flux, the ratio of ACPs to corrosion products in the coolant is larger than that on the pipe surface, so there is a net flow of ACPs from the coolant to the pipe surface. Through this process, ACPs are transported from the in-flux pipe to the out-flux pipe, which is described in Figure
Transport process of ACPs in the cooling loop based on the three-node model.
In brief, the three-node transport model is based on the theory that the main driving force for ACPs transport is the temperature change of the coolant throughout the loop and the resulting change in metal ion solubility in the coolant. So whether it is PWR temperature range (280~320°C) or ITER temperature range (140~180°C), the three-node transport model is all applicable.
In CATE, the corresponding equations are as follows:
In the above model, some assumptions are made, including the following: (1) the concentration of nuclides in the coolant keeps the same along the cooling loop, which is because it takes the coolant only several seconds to circle around the cooling loop, which means the homogenization effect of nuclides in the coolant is dominant; (2) the influence of activation and decay on the mass of corrosion products is neglected because the quantity of ACPs is very limited compared to that of corrosion products; (3) the concentration of nuclides on the pipe surface is equal to its solubility in the adjacent coolant.
To solve the above differential equations, the fourth-order Runge-Kutta method is used, which is fast and can control the error well. Moreover, an algorithm of adaptive time step is adopted in CATE for determining the time step reasonably and the calculation speed can be improved.
MIT PCCL was chosen here to test the code CATE, which is a small scale loop operated under constant coolant chemistry in the MIT reactor to closely simulate the primary circuit of a typical PWR power plant. The main operation data of the loop is presented in Table
The operation data of MIT PCCL.
Parameter | Value |
---|---|
Temperature (°C) | 273.9~315.6 |
Mass flow rate (kg/s) |
|
Flow velocity (m/s) | 2.83~3.18 |
Volume of coolant (m3) |
|
Surface area of in-flux pipe (m2) |
|
Surface area of out-flux pipe (m2) |
|
Mass flow rate in CVCS (kg/s) |
|
Collection efficiency of CVCS | 50% |
Concentration of boron (ppm) | 800 |
Concentration of LiOH (ppm) | 1.84 |
Concentration of H2 (cc/kg-H2O) | 25 |
The base metal of in-flux pipe is Zircaloy-4 and the corrosion rate of this material is nearly 0. The base metal of out-flux pipe is mainly Inconel and the corrosion rate of it is
The surveillance data from MIT PCCL for 42 days of full power operation was published, and the radioactivity of ACPs in the loop is as shown in Table
Radioactivity of ACPs in MIT PCCL after normal operation for 42 days.
Data source | Radioactivity of ACPs (GBq) | |||||
---|---|---|---|---|---|---|
In-flux pipe | Coolant | Out-flux pipe | ||||
Co-58 | Co-60 | Co-58 | Co-60 | Co-58 | Co-60 | |
MIT |
|
|
|
|
|
|
CATE |
|
|
|
|
|
|
Calculation results from CATE are close to the experimental results from MIT, which means CATE is available and credible on ACPs analysis of water-cooled nuclear reactor. The calculation results of mass of corrosion products in the in-flux pipe, the coolant, and the out-flux pipe are, respectively,
The International Thermonuclear Experimental Reactor (ITER) is under construction now. In its design plan, the primary cooling loops are most water-cooled, such as the blanket, the divertor, the NB injector, and the vacuum vessel. So ITER can be treated as a representative of water-cooled fusion reactor. China is developing its own fusion reactor CFETR (China Fusion Engineering Test Reactor), whose design plan of heat transfer and radiation shielding partly refers to ITER, so ACPs analysis of ITER will benefit the work of source term control for CFETR.
The planned operation data of ITER blanket cooling loop is presented in Table
The planned operation data of ITER blanket cooling loop.
Parameter | Value |
---|---|
Temperature (°C) | 140~174 |
Mass flow rate (kg/s) | 851 |
Average flow velocity (m/s) | 4.0 |
Volume of coolant (m3) | 33.36 |
Surface area of in-flux pipe (m2) | 991.4 |
Surface area of out-flux pipe (m2) | 1395.1 |
Mass flow rate in CVCS (kg/s) | 2.55 |
Collection efficiency of CVCS | 50% |
Concentration of H2 (cc/kg-H2O) | 25 |
The base metal in in-flux pipe and out-flux pipe is the same kind of stainless steel, SS316, and the corrosion rate of it is as follows:
The above equation and the element composition of SS316 are quoted from [
The neutronics model of the chosen blanket module (marked with a red ring).
The neutron spectrum of the chosen blanket module.
After 1.2 years of full power operation, the mass of corrosion products and the radioactivity of ACPs in the loop are as shown in Table
Calculation results of ACPs in ITER blanket cooling after normal operation for 1.2 years from CATE.
In-flux pipe | Coolant | Out-flux pipe | |
---|---|---|---|
Mass of corrosion products (kg) |
|
|
|
Radioactivity of ACPs (GBq) |
|
|
|
From Table
We also can see that ACPs radioactivity on the pipe surface is much higher than that in the coolant, which means the pipe surface is the main radioactive contamination region and should be decontaminated regularly through water chemistry method. The specific radioactivity of ACPs in the in-flux pipe, the coolant, and the out-flux pipe is calculated as
From Table
The main ACPs after normal operation for 1.2 years from CATE.
Nuclide | Half-life | Radioactivity (GBq) | ||
---|---|---|---|---|
In-flux pipe | Coolant | Out-flux pipe | ||
V-49 | 330 d |
|
|
|
V-52 | 3.74 m |
|
|
|
V-53 | 1.6 m |
|
|
|
Cr-51 | 27.7 d |
|
|
|
Cr-55 | 3.50 m |
|
|
|
Mn-56 | 2.58 h |
|
|
|
Fe-55 | 2.74 y |
|
|
|
Fe-59 | 44.5 d |
|
|
|
Co-57 | 272 d |
|
|
|
Co-58m | 9.04 h |
|
|
|
Co-58 | 70.9 d |
|
|
|
Co-60m | 10.5 m |
|
|
|
Co-60 | 5.27 y |
|
|
|
Ni-57 | 35.6 h |
|
|
|
Ni-63 | 100 y |
|
|
|
|
||||
Total |
|
|
|
|
Short-lived |
|
|
|
The ARShield code developed by NCEPU of China is applied to dose rate calculation, which is a new version of the point kernel integration code QAD-CG developed by Los Alamos National Laboratory. ARShield breaks some restrictions of QAD-CG, such as complicated modeling, complicated source setting, 3D fine mesh results statistics, and large-scale computing efficiency, and is proved to be reliable and efficient on dose rate calculation.
The density of each radionuclide at chosen regions calculated by CATE is introduced into ARShield and then converted to dose rate using point kernel integration method, which is as follows:
The geometry of hot leg pipe in ITER blanket cooling loop is adopted to represent the region of out-flux pipe, which has an internal diameter of 0.527 m, thickness of 0.02 m, and length of 33 m. The dose rate around the hot leg pipe calculated by ARShield is shown in Figure
Variation of dose rate with the distance from the outer surface of the hot leg pipe.
We can see that after shutting down the reactor for 8 days, the dose rate is much lower than that of normal operation for 1.2 years, which is because that contribution from the short-life ACPs decreases almost to zero after shutdown for 8 days. The typical values of dose rate are as follows: during normal operation, the dose rate at the outer surface of the pipe is 8.80 mSv/h, and the dose rate at a distance 1 m away from the outer surface of the pipe is 2.52 mSv/h; after shutdown for 8 days, the values drop to 1.05 mSv/h (contact) and 0.31 mSv/h (1 m away). When these values are compared to the annual permissible worker dose rate of 20 mSv/year, recommended by the ICRP [
In this paper, a three-node transport model was introduced into the ACPs source term code CATE, making CATE capable of theoretically simulating the variation and the distribution of ACPs in a water-cooled reactor and suitable for more operating conditions. MIT PCCL was chosen to test the new version of CATE, and the calculation results from CATE are close to the experimental results from MIT, which means CATE is available and credible on ACPs analysis of water-cooled reactor. Then the radioactivity and composition of ACPs in ITER blanket cooling loop were analyzed using CATE and the results showed that the major contributors are the short-life nuclides (V-52, V-53, Cr-55, Mn-56, Co-58m, Co-60m, and Ni-57) for ITER, especially Mn-56. That is very different from PWR, in which the long-life nuclides Co-58 and Co-60 are the main ACPs. At last, the dose rate around ITER blanket cooling loop caused by ACPs was calculated through coupling the code CATE with a point kernel integration code ARShield. The results showed that after shutting down the reactor only for 8 days, the dose rate can decrease nearly one order of magnitude compared to that of normal operation, which is caused by the rapid decay of the short-life ACPs. In the future, CATE will be applied for ACPs analysis of Chinese water-cooled fusion reactor CFETR as soon as its design plan is completed.
The authors declare that they have no competing interests.